A boiler that won’t fire up always seems to happen on the coldest morning of the year. The good news is that a lot of the no-fire calls we get turn out to have a simple cause, one you can often check yourself in a few minutes.

We’ve been servicing and repairing gas boilers across Glasgow, Lanarkshire, Renfrewshire and Ayrshire for over 30 years. Here are the six checks we’d ask you to try first, and the faults that need a Gas Safe engineer. If you’d rather go straight to a repair, you can book one here.

Six checks to try first

1. Is the gas getting through?

Try lighting your gas hob, if you have one. If that doesn’t work either, the problem is with your gas supply, not the boiler. If you have a prepayment meter, check it’s in credit.

2. Does the boiler have power?

Check the display is lit. If not, check the fused spur switch next to the boiler and your fuse box for a tripped switch.

3. What’s the boiler pressure?

If the pressure gauge is below 1 bar, your boiler may refuse to fire. Top it up following our guide to why a boiler loses pressure.

4. Is the thermostat calling for heat?

Turn the thermostat up above room temperature, check the timer is set to on, and replace the thermostat batteries if it’s wireless.

5. Is the condensate pipe frozen?

In freezing weather, a frozen condensate pipe is one of the most common reasons a boiler stops firing. It’s often an easy fix with warm water.

6. Reset the boiler once

Press the reset button and wait a few minutes. If the boiler fires and stays on, keep an eye on it. If it locks out again, don’t keep resetting it. Repeated resets can lock the boiler out completely.

What does the lockout light or fault code mean?

When your boiler shows a fault code or a lockout light, it’s protecting itself. It has detected something wrong and shut down safely. Make a note of the code before you call us. It helps our engineer know what to look for and what parts to bring.

Ignition faults that need an engineer

If you’ve tried the checks above and the boiler still won’t fire, the cause is usually one of these. Every one of them needs the casing off, so they’re jobs for a Gas Safe engineer only.

  • Faulty ignition electrode or lead. If the spark isn’t strong enough, the gas won’t light. You may hear clicking without the boiler firing.
  • Faulty flame sensor. The boiler lights briefly, then shuts down because it can’t detect the flame.
  • Gas valve fault. The valve isn’t opening to let gas through to the burner.
  • Fan failure. The boiler won’t fire if it can’t confirm the fan is clearing the flue safely.
  • PCB fault. The printed circuit board is the boiler’s brain. When it fails, the boiler can’t run its start-up sequence.

Our engineers will diagnose the fault, explain it in plain terms, and give you a clear quote before fitting any parts.

How quickly can we get to you?

Our engineers are local, directly employed, and work from our main office in East Kilbride and our offices in Ayr and Kilmarnock. There’s someone to speak to 24/7, 365 days a year. One customer told us their engineer came out on a Saturday night and made sure the heating and hot water were back on before he left. We cover Hamilton, Blantyre, Girvan, Alloway and right across Glasgow, Lanarkshire, Renfrewshire and Ayrshire.

When to call an engineer

  • You’ve tried the six checks and the boiler still won’t fire
  • The boiler locks out again after one reset
  • You can hear clicking but the boiler won’t light
  • The boiler lights then cuts out
  • There’s a fault code you don’t recognise

Get your boiler working again

Our Gas Safe engineers are all directly employed, with no subcontractors. We’re rated 4.5 out of 5 on Google from over 330 reviews.

Call our main office in East Kilbride on 01355 203 333, Ayr on 01292 833120 or Kilmarnock on 01563 594361. Or WhatsApp us on 07344081873. You can also book a repair online.

Frequently asked questions

Why does my boiler try to ignite then stop?

This usually points to a flame sensor fault, a gas supply problem or a blocked condensate pipe. If a reset doesn’t fix it, call an engineer.

How many times should I reset my boiler?

Once. If it locks out again, there’s a fault that needs a Gas Safe engineer. Repeated resetting can lock it out completely.

Can low pressure stop my boiler firing?

Yes. Most boilers won’t fire if the pressure drops below about 1 bar. Topping it up often fixes the problem.

Do you offer emergency call-outs at weekends?

There’s always someone to speak to 24/7, 365 days a year. Call our office and we’ll get an engineer to you as quickly as we can.